Skip to content
We independently pick everything we recommend. We earn a commission when you buy through our links, at no extra cost to you. Learn more ›
Amazon Black Friday Week deals

How Do You Use a Digital Multimeter: A Maker Guide

Learn how do you use a digital multimeter to measure voltage, check continuity and resistance, and measure current safely on bench and household circuits.

How Do You Use a Digital Multimeter: A Maker Guide
On this page

Top picks at a glance

As an Amazon Associate I earn from qualifying purchases.

  1. 1Fluke 117 Digital MultimeterFluke 117 Digital Multimeter9.7/10View on Amazon
  2. 2Fluke 17B+ Digital MultimeterFluke 17B+ Digital Multimeter9.6/10View on Amazon
  3. 3AstroAI Digital Multimeter, TRMS 4000 CountsAstroAI Digital Multimeter, TRMS 4000 Counts9.6/10View on Amazon
  4. 4Klein Tools MM450 Slim Digital MultimeterKlein Tools MM450 Slim Digital Multimeter9.5/10View on Amazon

When a lamp stays dark, a solder joint looks dull, or a battery powered project stops responding, the cause is often a loose connection, a dead cell, or a missing supply, and learning how do you use a digital multimeter turns that guesswork into a clear reading on a display. Depending on the model, a digital multimeter measures voltage, current, resistance, continuity, capacitance, frequency, temperature and diode forward voltage drop, and the steps below show how to set the dial, connect the leads, place the probes, and read the result.

LaserEngraveHQ earns a commission from purchases made through these links, at no extra cost to you. Read our affiliate disclosure.

Safety note

Work with the power off when checking continuity or resistance, keep fingers behind the probe guards, and match the meter rating to the circuit. A meter rated CAT III 600V suits common residential, commercial and industrial settings, as the maker of the Fluke 17B (on Amazon)+ states.

Fluke 117 Digital Multimeter

Fluke 117 Digital Multimeter

Fluke9.7/10 HQ Score
i
The HQ Score runs from 9.2 to 9.8 and weighs performance (35%), build (25%), value (25%), safety (10%, where it applies) and warranty (5%), using only what the manufacturer and the listing publish. How we pick ›

A True RMS meter with AutoVolt automatic AC and DC selection, VoltAlert non contact voltage detection, and a 3 years warranty, for voltage, resistance, continuity, frequency, capacitance and Min Max Average work.

Pros

  • AutoVolt automatic AC and DC voltage selection removes dial guesswork on voltage work
  • VoltAlert non contact voltage detection finds live AC voltage without touching the conductor
  • True RMS gives accurate readings on non linear loads, per the maker
  • DC millivolts range of 600.0 mV with 0.1 mV resolution suits low voltage electronics

Cons

  • No CAT rating is stated, so the safety rating is unclear from the facts given
  • Battery life of 400 hours typical applies without backlight, so backlight use shortens run time
  • Low input impedance mode needs care on sensitive circuits where loading can change a reading
  • No temperature measurement is stated, unlike the Fluke 17B+ and the Klein Tools MM450
Fluke 17B+ Digital Multimeter

Fluke 17B+ Digital Multimeter

Fluke9.6/10 HQ Score
i
The HQ Score runs from 9.2 to 9.8 and weighs performance (35%), build (25%), value (25%), safety (10%, where it applies) and warranty (5%), using only what the manufacturer and the listing publish. How we pick ›

A Fluke meter for electrical applications, measuring AC and DC voltage to 1000V and current to 10A, plus resistance, continuity, diode mode, capacitance, frequency and temperature to 400C.

Pros

  • AC and DC voltage to 1000V and current to 10A cover a wide range of electrical applications
  • Temperature measurement to 400C with the included type K thermocouple suits heating and cooling systems
  • CAT III 600V safety rating suits residential, commercial and industrial settings
  • Diode mode helps identify faulty diodes quickly during repair work

Cons

  • No concrete warranty term is stated, only a manufacturer warranty with no term given
  • Dimensions of 8.46 inches x 2.76 inches x 5.91 inches make it the largest meter in this guide
  • No backlight or non contact voltage detection is stated
  • No battery life figure is stated
AstroAI Digital Multimeter, TRMS 4000 Counts

AstroAI Digital Multimeter, TRMS 4000 Counts

AstroAI9.6/10 HQ Score
i
The HQ Score runs from 9.2 to 9.8 and weighs performance (35%), build (25%), value (25%), safety (10%, where it applies) and warranty (5%), using only what the manufacturer and the listing publish. How we pick ›

A TRMS 4000 Counts auto ranging meter that measures AC and DC voltage to 600V, current to 10A and resistance to 40MΩ, with diode mode, battery modes for 1.5V, 9V and 12V batteries and NCV detection.

Pros

  • TRMS 4000 Counts auto ranging meter measures AC and DC voltage to 600V and current to 10A
  • Battery modes for 1.5V, 9V and 12V batteries cover common household and automotive cells
  • NCV detection with sound and light alarms finds AC voltage without the use of leads
  • Data Hold, Max, auto shut off, low battery indicator, backlit screen and flashlight aid everyday use

Cons

  • No warranty term is stated
  • Resistance to 40MΩ is lower than the 50MΩ stated for the Klein Tools MM450
  • Two 1.5V AAA batteries are included, so spares are needed once those cells run down
  • No temperature measurement is stated, unlike the Fluke 17B+ and the Klein Tools MM450
Klein Tools MM450 Slim Digital Multimeter

Klein Tools MM450 Slim Digital Multimeter

KLEIN TOOLS9.5/10 HQ Score
i
The HQ Score runs from 9.2 to 9.8 and weighs performance (35%), build (25%), value (25%), safety (10%, where it applies) and warranty (5%), using only what the manufacturer and the listing publish. How we pick ›

A slim auto ranging TRMS meter that measures AC and DC voltage up to 600V, 10A AC and DC current and 50MΩ resistance, with continuity, temperature, capacitance, frequency and duty cycle, plus diode mode.

Pros

  • AC and DC voltage up to 600V, 10A current and 50MΩ resistance cover household, automotive and light industrial work
  • Lead Alert LEDs show proper lead placement, which aids accuracy and safety during measurements
  • Reverse contrast display gives a large, high visibility reading in all lighting conditions
  • Slim profile fits into most pockets, and the meter withstands a 6.6-Foot (2 m) drop

Cons

  • Warranty details are given only as a call to the vendor, with no term stated
  • Voltage to 600V is lower than the 1000V stated for the Fluke 17B+
  • Slim size may feel small for a maker who prefers a larger meter body
  • No non contact voltage detection is stated, unlike the Fluke 117 and the AstroAI M4K0R

How do you use a digital multimeter step by step

With the circuit off for resistance and continuity work, set the dial for the quantity to measure. Connect the black lead to the common socket and the red lead to the socket for voltage, resistance or current, as marked on the meter. Place the probes on the points to measure, hold them steady, and read the display. For voltage work, connect the probes across the component or supply. For current work, the meter must sit in series with the circuit, and the dial must be set for current before the probes touch the circuit.

  • Set the dial: choose voltage, current, resistance, continuity, capacitance, frequency or diode mode.
  • Connect the leads: black lead to common, red lead to the marked socket.
  • Place the probes: touch the probe tips to the measurement points and keep them steady.
  • Read the display: note the value and the unit, then remove the probes.

Auto ranging meters choose the range for the reader. The best multimeter for beginners guide explains how auto ranging and a clear display help new makers, and the breadboard guide shows where probes meet a project circuit.

Measure voltage with a digital multimeter

Voltage is measured across a component or supply, with the probes in parallel. Set the dial to AC voltage for mains and household alternating supplies, or DC voltage for batteries and low voltage electronics. For a DC supply, touch the red probe to the positive side and the black probe to the negative side or common, then read the display. For an AC supply, probe polarity does not change the reading. A reading near the expected supply value points to a live supply, while a reading near zero points to a missing supply or an open connection upstream.

The Fluke 117 (on Amazon) adds AutoVolt automatic AC and DC voltage selection and VoltAlert non contact voltage detection. The AstroAI M4K0R measures AC and DC voltage to 600V, the Klein Tools MM450 (on Amazon) measures AC and DC voltage up to 600V, and the Fluke 17B+ measures AC and DC voltage to 1000V, while its CAT rating is CAT III 600V.

Check continuity and resistance

Continuity and resistance are measured with the power off, because a live circuit can damage the meter and give a false reading. Set the dial to continuity or resistance, touch the probes together to confirm the meter responds, then place the probes across the wire, fuse, switch or joint in question. A continuity buzzer sounds when the path is complete, and an open path shows an overload or out of range indication.

Use this mode to find a broken wire, a blown fuse, or a cold solder joint. The how to use a soldering tool guide covers joints that often need this kind of check.

Measure current, capacitance, frequency and temperature

Current is measured in series, with the dial set for current and the red lead in the current socket. The Fluke 17B+, the AstroAI M4K0R and the Klein Tools MM450 measure current to 10A, and the dial must be set for current before the circuit is powered. The Fluke 17B+ measures temperature up to 400C with the included type K thermocouple, which suits heating and cooling systems. The Klein Tools MM450 also measures temperature, capacitance, frequency and duty cycle, plus diode mode. Diode mode measures the forward voltage drop of a diode and helps identify a faulty diode.

Meters that cover voltage, continuity, resistance and current

Together, the meters below cover the steps above, from voltage and continuity checks on a bench project to current, capacitance, frequency and temperature work on household and automotive circuits.

Common mistakes to avoid

  • Measuring resistance or continuity with the power on.
  • Leaving the red lead in the current socket for a voltage reading.
  • Choosing a current mode for a voltage measurement.
  • Ignoring the CAT rating and using a meter beyond its stated rating.

FAQ: lasers and CNC

How do you use a digital multimeter to measure voltage?

Set the dial to AC or DC voltage, connect the black lead to common and the red lead to the voltage socket, then touch the probes across the component or supply and read the display. The Fluke 117 selects AC or DC voltage automatically with AutoVolt.

What does CAT III 600V mean on a digital multimeter?

CAT III 600V is a safety rating for work on electrical systems in common residential, commercial and industrial settings, as the maker of the Fluke 17B+ states. The AstroAI M4K0R also carries a CAT III 600V rating, and the Klein Tools MM450 includes leads with CAT III and CAT IV safety caps.

Can a digital multimeter check a battery?

Yes, set the dial to DC voltage and touch the probes to the battery terminals, red to positive and black to negative. The AstroAI M4K0R also includes battery modes for 1.5V, 9V and 12V batteries, with a red light for low voltage and a green light for enough voltage.

Why does a digital multimeter show an overload reading on resistance?

An overload or out of range indication on resistance usually means the path is open, the probes are not making contact, or the resistance is above the selected range. Check the probe contact, confirm the power is off, and confirm the dial is set to resistance.

Which digital multimeter suits electronics work on a bench?

A meter with True RMS, a clear backlit display, and a low voltage range can suit bench electronics. The Fluke 117 offers True RMS, a large white LED backlight, DC millivolts with a range of 600.0 mV and a resolution of 0.1 mV, plus a battery life of 400 hours typical without backlight. The best multimeter for electronics guide compares more meters for bench work.

Related: the electronics making hub, best multimeter for beginners and best multimeter for electronics. Also see the multimeter vs clamp meter guide.

More buying guides